Number 10 / 2026
To download all number in format PDF (in Russian)The further text is accessible on a paid subscription. For authorisation enter the login/password. Or subscribe
Number maintenance (pdf) (doc)
Number abstract (doc)
Literature lists to articles (doc)
|
UDC 556.18:628.16 DOI 10.35776/VST.2026.10.01
Gnezdilov Aleksei
Topical issues and strategical lines of developing water supply systems in the new regions through the example of the Kherson Region
Summary
Based on an analysis of the topical water use issues in the new regions, strategical lines of developing water supply systems are presented through the example of the Kherson Region. Possible options are outlined for using parts of the Kherson Region land reclamation network – specifically, isolated hydraulic structures, for cumulating water reserves for the subsequent supply and partial rehabilitation of the irrigation system operation. The expediency of justifying the strategical development plans for the water supply systems in these regions basing on estimating the sustainability of the systems defined by the ability to maintain their integrity and operational status over a specific period is shown. Four levels of the water supply system sustainability are analyzed, and recommendations are provided for ensuring the sustainability with account of the specific characteristics of the water use schemes in the new regions. It has been shown that local water resources in the new regions currently determine the development priorities for the water supply systems, criteria for their estimation, and optimal utilization options.
Key words
ground water , water supply system , water resources , mineralization , integrated management , sustainability , infrastructure
|
UDC 628.161:544.723 DOI 10.35776/VST.2026.10.02
Gora Natalia, Chernyshev Daniil, Belyaeva Oxana, Gurinovich Galina, Ivanova Vera
On the use of new carbon materials for removing iron from groundwater
Summary
The results of studying the use of carbon sorbents to reduce iron ion concentrations during groundwater purification in Kuzbass are presented. The texture and surface chemical characteristics of the selected Purolat-Standard carbon material are described. It has been established that the structure of this sorbent is pore-free, and a small number of acid groups are detected on its surface. Possible increasing the sorbent capacity by attaching an amino acid to its surface is investigated. The state of the sorbent surface after fitting modifiers is analyzed. The results of the experimental studies of iron adsorption equilibrium on the modified sorbent samples are presented. Modification with both an amino acid and a mixture of acids results in an increased iron ion adsorption. Modification with a mixture of acids proved to be the most effective.
Key words
cleansing , ground water , iron , modified carbon sorbents
|
UDC 628.11:628.14:614.78 DOI 10.35776/VST.2026.10.03
Frog Dmitrii
Analysis and lines of approaching the problem of water supply pressure deficiency in buildings
Summary
The conclusions of the «Use of hydraulic accumulators for water supply systems in buildings and structures with 5–9 stories», research project conducted by NIISF RAASN in 2026 under the Ministry of Construction of the Russian Federation R&D plan are presented. The international and domestic experience, relevant regulations, and the big picture evaluating the potential approaches to meeting the water supply requirements – specifically regarding pressure – for buildings and tenement houses are analyzed. The key patterns identified through analyzing outdoor and inside water pipelines in buildings up to 27 meters in height are presented. Based on the analysis of the hydraulic operating conditions the most likely (best available) solutions to address water shortages for the consumers on the upper floors of 5–9-storied buildings during peak demand are identified. Possible configurations for pressure-regulating units within the inner ducts of apartment buildings are presented. Conditions have been formulated for the technical equipping of the units designed to maintain specified pressure in the water distribution systems of multi-apartment buildings. Design considerations and component selection principles for the pressure-regulating units are discussed. The operational adaptability of the equipment used in pressure-regulating units and backup water sources is described.
Key words
water supply , pressure , free pressure , backup water sources , unit design to maintain the specified pressure
|
UDC 628.12:621.316.718 DOI 10.35776/VST.2026.10.04
Grigoriev Aleksei, Kulikova Lidiia
Use of variable-speed drives in water supply systems: need for readjusting once the operating conditions stabilize
Summary
A system analysis was conducted regarding the operating modes of a variable-speed drive of a submersible pump unit at water supply facilities where the water tower was replaced. It was demonstrated that the initial setup of the converter unit – performed immediately after a long downtime of the system – is executed under conditions of nonstationary water draw-off and distribution network packing; consequently, the sleep mode parameters, operating frequency limits, and PID controller coefficients may not align with the parameters required for the subsequent routine operation. The study novelty lies in identifying measurable operational indicators that signal the completion of the transient process, and in substantiating a two-stage commissioning procedure. The quantitative estimation was based on the field monitoring data of four pump units (7.5–18.5 kW capacity) at the water intake facilities serving rural settlements in the Altai Territory over a seven-day period. Following the transient phase, the average operating frequency decreased by 1.53–2.39 Hz (3.37–5.93%), the maximum pressure deviation from the setpoint dropped by 0.35–0.56 bar (63.2–84.8%); and the total duration of the sleep mode operation ranged from 8.67 to 11.5 hours. It was demonstrated that the residual pressure deviation – normalized against the setpoint – converged to a range of 7.3–9.5% across all sites, and was determined by the control loop settings rather than by the network characteristics. The need to re-parameterize the drive once the water consumption stabilizes is substantiated; and the benefits of remote monitoring and commissioning as components of the digital control systems for the water supply facilities are highlighted.
Key words
frequency-regulated electric drive , remote monitoring , submersible pump , digitalization , underground water supply , PID controller , sleep mode , transient process , experimental monitoring
|
UDC 628.242-784.43 DOI 10.35776/VST.2026.10.05
Svitskov S. V., Malykh Ol’ga, Chaikin Evgenii
Experience in addressing the odor problem at a wastewater pumping station in Barnaul
Summary
The issue of malodorous emissions is considered through the example of a wastewater pumping station in Barnaul that became a target of local resident discontent due to unpleasant odors. The study analyzes the data collected to validate the complaints, identify the causes of the malodors, and develop a technical solution. The results of measures implemented following the study, aimed at improving the urban environment and living conditions of the residents. A technical solution was developed and implemented involving increasing the stack height and retrofitting a second, adsorption-based stage of gas purification at the facility.
Key words
odor , reeking substances , adsorption , olfactometry , wastewater pumping station
|
UDC 628.356.1 DOI 10.35776/VST.2026.10.06
Kaplun Roman
Calculating aeration in aeration tanks: common errors in determining airflow rate and ways to prevent them
Summary
Aeration is one of the most energy-intensive processes in biological wastewater treatment; accordingly, errors in determining the required airflow rate directly affect the operational reliability and energy consumption of treatment facilities. The aim of this study is to systematize the calculations regarding oxygen transfer in aeration tanks, elucidate the physical significance of the key parameters, and identify the causes of common engineering errors. The analytical framework relies on the oxygen transfer mass balance equations, SOTE and eSOTE metrics, correction factors for converting from standard to operating conditions, as well as the WEF MOP 8 data and published research on α-factor. The effect of the aerator submergence depth, temperature, atmospheric pressure, wastewater composition, total suspended solids (TSS) concentration, operational condition of the aeration system, and dissolved oxygen concentration was examined. By way of a calculation example at 22 °C water temperature, 4.75 m aerator installation depth, 28% SOTE guide value, 3.5 g/L TSS, and 455 kg/h actual oxygen requirement (AOR), α ≈ 0.44 values and approximately 19,3 Nm3/h required airflow rate were obtained. Since SOTE in the example is determined using a simplified relationship based solely on depth, the indicated airflow rate should be regarded as a forward estimate sensitive to the airflow rate through the diffuser and its placement density. It is demonstrated that the mechanical multiplication of SOTE by the aerator submergence depth in combination with excluding the air oxygen mass concentration from the balance, yields physically and dimensionally incorrect results. The practice effect of the proposed approach lies in establishing a transparent calculation sequence that provides for the justification of the initial coefficients and verification of the results against the specific performance indicators.
Key words
biological treatment , aeration , energy efficiency , aeration tank , air flow rate , dissolved oxygen , SOTE , eSOTE , α-factor
|
UDC 624.041 DOI 10.35776/VST.2026.10.07
Zakharov Iurii
Comparative analysis of the methods of the static calculation of underground gravity wastewater pipelines
Summary
The long-term service and integrity of pipelines are of great economic importance. Consequently, it is crucial to pay close attention to the design quality of pipeline systems. Static calculation of pipelines is performed to verify the robustness of the designed structures against projected loads to eliminate the degradation of the operational performance or environmental damage. A comparative analysis is presented regarding advanced static analysis methods for underground gravity wastewater pipelines, as developed by the American and German research communities. Recommendations are provided for choosing the methods of calculating ground pressure on underground pipelines and pipeline installation.
Key words
pipeline , water disposal system , ground , static calculation , pipes
|
UDC 628.22/.25:711.4-16(510) DOI 10.35776/VST.2026.10.08
Kofman V. Ya., Bubelo Ol’ga
«Sponge city». Chinese stormwater management strategy (a review)
Summary
The expansion of urban development using traditional building materials leads to the removal of the natural environment that retains stormwater, as well as the creation of impermeable surfaces that cannot absorb rainwater, resulting in urban flooding. In many cases, stormwater is discharged as wastewater, when it could be used for groundwater recharge, domestic and agricultural applications. To address these issues, China initiated the creation of a new urban water management system known as the «Sponge City» in 2013–2014. In 2015–2016, 30 urban areas began implementing pilot projects with the intention of processing most of the stormwater through the new infrastructure. The goal of the «Sponge City» concept is to mitigate the impact of urban development on natural ecosystems and simultaneously solve the problems of urban water supply. By 2030, it is planned to be implemented in 80% of the country’s urban areas.
Key words
rain water , China , stormwater , «Sponge City» , permeable surfaces , bio-retention , green roofs
|
|