№4|2017

HOT WATER SUPPLY

bbk 000000

UDC 697.34

Rafal'skaia T. A., Mansurov R. Sh.

Evaluation of the water temperature in the hot water system effect on the indoor temperature conditions

Summary

In the modern centralized heat supply systems two breakpoints of the central control heating curve are used. According to the effective regulative documents on ensuring the quality of hot water the temperature of supplied hot water should be raised in order to improve its microbiological characteristics. For this purpose the lower breakpoint of the central control heating curve was raised. At the same time in view of the impossibility of maintaining high temperature heating curves of the heat sources the upper breakpoint of the hea­ting curve is used. However in the present day schemes of heat supply stations coordinated heat supply to the systems of hot water and heat supply is used. The effect of temperature breakpoints on the indoor conditions was studied. A comparative checking calculation of the heating curves of a heat supply station in 2011–2012 was carried out when two breakpoints of the heating curve were used and in 2014–2015 when the upper breakpoint was raised (the lower breakpoint was raised too). The indoor temperature was determined with account of various building heat accumulation coefficients at different outdoor temperatures and variable water consumption in the hot water system. The calculations showed that raising the lower breakpoint produced more significant effect on the indoor heat conditions compared to the effect of raising the upper breakpoint. Raising the temperature in the hot water system can cause unfavorable heat conditions in the heated space; therefore raising the lower breakpoint cannot be considered as an energy efficient solution of the problem. Eliminating the drawbacks in the operation of hot water systems as well as carrying out regular thermal water disinfection can ensure meeting the requirements of the effective regulative documents eliminating deterioration of the heat supply quality.

Key words

, , , , , ,

The further text is accessible on a paid subscription.
For authorisation enter the login/password.
Or subscribe

REFERENCES

  1. Nauchno-metodicheskoe obosnovanie mikrobiologicheskoi bezopasnosti snizheniia temperatury goriachei vody v sistemakh vodosnabzheniia zakrytogo tipa [Scientific-methodological substantiation of microbiological safety of lowering hot water temperature in closed-type water supply systems. Moscow, FGBU FNIITSEM Publ., 2015, 48 p.].
  2. Petrushchenkov V. A. [Substantiation of the lowered heating curves in centralized heat supply system control]. Novosti Teplosnabzheniia, 2015, no. 8, pp. 30–37. (In Russian).
  3. Gershkovich V. F. [One hundred fifty… Norm or overkill? (Reflections on the heat conductor parameters)]. Energosbere­zhenie, 2004, no. 5, pp. 14–19. (In Russian).
  4. Rafal’skaia T. A. [Heat and hydraulic conditions of the centralized heat supply systems. Topical issues of engineering sciences: theoretical and practical aspects]. Ufa, Aeterna Publ., 2016, issue 5, pp. 116–171. (In Russian).
  5. Maliavina E. G., Tsygankov A. V. [Effect of different factors on the rate of indoor cooling after heat supply cutoff]. Izvestiia Vuzov. Stroitel’stvo, 2015, no. 2, pp. 53–59. (In Russian).
  6. Perekhozhentsev A. G. [Regulation of heat transmission resistance of cladding by indoor thermal comfort]. Vestnik MGSU, 2016, no. 2, pp. 173–185. (In Russian).
  7. Bodrov V. I., Koriagin M. V. [Method of calculating heat conditions in low-cost housing during the period of «temperature breakpoints»]. Izvestiia Vuzov. Stroitel’stvo, 2007, no. 2, pp. 42–46. (In Russian).
  8. Kononovich Iu. V. Teplovoi rezhim zdanii massovoi zastroiki [Heat conditions in low-cost housing. Moscow, Stroiizdat Publ., 1986, 157 p.].
  9. Popyrin L. S. [Natural and man-made failures in heat supply systems]. Vestnik RAN, 2000, v. 70, no. 7, pp. 604–610. (In Russian).